Optical Heart-Rate Sensing (PPG) Explained

How the green-light heart-rate sensor on watches and rings works, where it is accurate and where it is not, and why pulse rate variability is not the same as heart-rate variability.

Content last updated . This page has not been medically reviewed.

What it is

Most wrist and finger wearables read heart rate with photoplethysmography, or PPG. Heart rate from wearables is derived from PPG, an optical method for measuring changes in blood volume under the skin. [1] A light shines into the skin, a sensor reads how much comes back, and software turns the rhythm of those changes into a pulse rate. The same light-based approach underlies fingertip pulse oximeters, which estimate oxygen saturation and pulse rate. [2]

Direct versus derived:

OutputDirect or derived
Light signal over timeDirect measurement
Pulse rate (beats per minute)Derived from the timing of pulses
Pulse rate variability, "HRV" scores, readiness, stressDerived, often proprietary
Blood oxygen, blood pressure, irregular-rhythm flagsDerived from the signal by additional algorithms

What the evidence shows

Resting and steady heart rate is usually close. A Duke University study compared consumer- and research-grade wearables across activities. Devices were reasonably accurate at rest and at prolonged elevated heart rate, but absolute error during activity was on average 30% higher than at rest, and devices differed in how they followed changes in activity. [1] Label: mixed.

Model matters. In 60 healthy young adults, with a Polar H10 chest strap as the heart-rate reference, the Apple Watch 6 had a coefficient of variation under 5% across sitting, walking, running, resistance exercise and cycling, while the Polar Vantage V and Fitbit Sense ranged from high to poor accuracy depending on the activity. All three had poor accuracy for energy expenditure (calorie) estimates. [3] Results apply to those models and that group, not to newer versions or other people.

Wearable pulse rate can have wide error in individual readings. A meta-analysis of four wearable pulse-rate studies (176 people) found average biases near zero, but 95% limits of agreement of about -16 to +14 bpm for light skin pigmentation, -19 to +17 for medium and -34 to +33 for dark. The authors found no statistically or clinically significant average bias by skin pigmentation, though the small number of studies limits conclusions. [4] The Duke study found no statistically significant difference in heart-rate accuracy across skin tones, while noting that no earlier study had systematically explored the full range of skin tones. [1]

Known sources of error. The Duke authors named three: diverse skin types, motion artifacts and signal crossover. [1] For how fit, placement and skin affect readings, see fit, placement and skin characteristics.

Pulse rate variability is not heart-rate variability

Heart-rate variability (HRV) is normally calculated from the electrical signal of an ECG (see electrical heart-rate measurement). A PPG device measures pulse timing, so its version is called pulse rate variability (PRV). In 103 college football players, heart rate and pulse rate agreed closely, but PPG-based PRV values were lower than ECG-based HRV (rMSSD 80.9 ms versus 103.9 ms), and PRV caught fewer of the changes ECG-HRV identified, with an average delay of 1.8 to 5.5 days. The authors concluded PRV should not be treated as an equivalent substitute. [5] A 2026 meta-analysis of 10 studies found small pooled differences (absolute standardized error 0.188 for rMSSD) based mostly on resting or controlled conditions, and warned against generalizing to sleep, exercise, stress or everyday life. [6] Label for using PRV as a stand-in for HRV in daily life: insufficient evidence. For what HRV means, see heart-rate variability explained.

Accuracy is not benefit

Accurate pulse-rate readings do not show that checking them improves health. Raise any worry about your heart rate with a clinician instead of relying on a watch trend; see resting heart rate.

Who should be careful

People who notice palpitations, fainting, chest pain or breathlessness should seek care rather than relying on a watch; in the US, call 911 for severe symptoms. Do not change medicines because of a wearable reading. The FDA lists poor circulation, skin thickness, skin temperature and nail polish among factors that can affect light-based oximeter readings, so a poor signal can happen in some situations. [7]

How to evaluate a claim

Look for the exact device model, the reference (ECG chest strap or 12-lead), the activity tested, and whether limits of agreement (not just averages) are reported. See smartwatches: what they measure.

Frequently asked questions

How does a watch measure heart rate?

It shines light into the skin and measures changes in blood volume, a method called photoplethysmography. [1]

Is a wrist heart rate as accurate as a chest strap?

Not always. Accuracy varied by device and activity in a 60-person study with a chest strap reference, and error was higher during activity than at rest. [3][1]

Does skin tone change heart-rate accuracy?

One study found no significant difference across skin tones, and a meta-analysis found no significant average bias by pigmentation, though individual readings varied widely. [1][4]

Is the HRV on my watch the same as medical HRV?

No. A PPG device calculates pulse rate variability, which in a study of 103 athletes read lower than ECG-based HRV. [5]

Can optical sensors detect heart rhythm problems?

Some watches add features that look for irregular rhythm using this signal. Their regulatory status and test results are covered in consumer ECG and atrial fibrillation features.

More details: evidence, limits and cautions

The details behind this page: cautions, limits of the evidence and where sources disagree. Open any note to read it.

How to read the evidence labels

Labels used on this page: established, mixed, insufficient evidence, marketing claim.

References
  1. Investigating sources of inaccuracy in wearable optical heart rate sensors, NPJ Digit Med 2020 (PMID 32047863). Read 2026-10-22.
  2. U.S. Food and Drug Administration, Pulse Oximeter Basics, page current as of 03/26/2025. Read 2026-10-22.
  3. Wrist-worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense, Eur J Sport Sci 2023 (PMID 34957939). Read 2026-10-22.
  4. Singh S et al., Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis, J Med Internet Res 2024 (PMID 39388258). Read 2026-10-22.
  5. Pulse Rate Variability Is Not the Same as Heart Rate Variability: Implications for Sports Performance and Injury Prevention, Sports Med Open 2026 (PMID 42286401). Read 2026-10-22.
  6. Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis, Sensors (Basel) 2026 (PMID 42655500). Read 2026-10-22.
  7. U.S. Food and Drug Administration, Pulse Oximeters, page current as of 01/06/2025. Read 2026-10-22.
Education, not medical advice. This page is for general information. It does not diagnose or treat any condition and is not a substitute for care from a qualified health professional. Natural does not automatically mean safe. Ask a clinician or pharmacist before changing your care, especially if you take medication, are pregnant or breastfeeding, or have a health condition.